Type Accuracy class Max. capacity |
kg t |
C2 | |
0.2 50 − |
0.1 100, 200, 500 1, 2, 5, 10, 20, 50 | ||
Sensitivity (Cn) |
mV/V |
2 | |
Tolerance on sensitivity |
% |
< +0.20 | |
Temperature effect on sensitivity (TKC) in the nominal temperature range in the service temperature range |
%/10 K %/10 K |
< +0.05 < +0.10 | |
Temperature effect on zero balance (TK0) in the nominal temperature range in the service temperature range |
%/10 K %/10 K |
< +0.05 <+ 0.10 | |
Hysteresis error (dhy) Non-linearity (dlin) Creep (dDR) over 30 min. |
% % % |
< +0.15 < +0.20 < +0.10 < +0.06 | |
Input resistance (RLC) Output resistance (R0) |
Ω Ω |
340 ...450 356 + 0.2 | |
Reference excitation voltage (Uref) |
V |
5 | |
Nominal range of excitation voltage (BU) Max. permissible excitation voltage |
V V |
0.5...10 12 |
0.5...12 18 |
Insulation resistance (Ris) Nominal temoerarure range (BT) Operating temperature range (Btu) Storage temperature range (Btl) |
GΩ oC [oF] oC [oF] oC [oF] |
>5 - 10...+ 40 [14...104] - 30...+ 85 [-22...185] ( - 30...+ 120 ) 1) [-22...248]1 - 50...+ 85 [-58...185] | |
Safe load limit (EL) Breaking load (Ed Rel. static lateral load limit (Elq) Permissible dynamic load (Fsrel) (peak to peak acc. to DIN 50100) |
% of rated capacity |
130 |
150 |
300 50 100 | |||
Degree of protection class (IP) to EN 60 529 (IEC 529) Material: Measuring body Cable gland Cable sheath |
|
IP 68 (test conditions: 100 h at 1 m water column) IP 69 K (water at high pressure, steam jet cleaning) Stainless steel Nickel plated brass, Silicone Thermoplastic elastomer |