Type |
RSCC | |||||||
Accuracy class as per OIML R 60 Number of load cell verification intervals (nLC) |
C3 3000 | |||||||
Maximum capacity (Emax) |
50 kg |
100 kg |
200 kg |
500 kg |
1 t |
2 t |
5 t | |
Minimum load cell verification interval (vmin) Nominal (rated) sensitivity (CN) Sensitivity tolerance Zero signal |
% of Emax mV/V % mV/V |
0.0120 2 ±0.25 0 ±0.1 | ||||||
Temperature coefficient of sensitivity (TKC)1)
Temperature coefficient of zero signal (TK0) |
% of Cn / 10 K |
±0.0170 (20°C to 40°C) ±0.0110 (-10 °C to 20°C) ±0.0166 | ||||||
Relative reversibility error (dhy)1) Non‐linearity (dlin)1) Creep upon loading (dcr) over 30 min. |
% of Cn |
±0.0166 ±0.0166 ±0.0166 | ||||||
Input resistance (RLC) (nominal) Output resistance (R0) |
W |
389 ±15 350 ±1.5 | ||||||
Insulation resistance (Riso) |
GW/100 V |
> 2 | ||||||
Reference excitation voltage (Uref) Nominal (rated) supply voltage range (BU) |
V |
5 0.5 to 12 | ||||||
Nominal (rated) amb. temperature range (BT) Operating temperature range (Btu) Storage temperature range (Btl) Reference temperature (tref) |
°C |
-10 to +40 -30 to +70 -50 to +85 22 | ||||||
Limit load (EL) |
% of Emax |
150 | ||||||
Breaking load (Ed) |
200 |
300 |
200 | |||||
Relative perm. vibrational stress (Fsrel) (oscillation width as per DIN 50100) |
70 | |||||||
Nominal (rated) displacement at maximum capacity (snom), ±0.05 mm |
mm |
0.35 |
0.4 |
0.35 |
0.1 |
0.2 |
0.2 |
0.4 |
Weight (G), approx. |
kg |
0.7 |
1 |
1.4 |
1.7 |
2.2 | ||
Degree of protection per EN 60 529 (IEC 529) |
|
IP 68 (test conditions 1 m water column / 100 h) | ||||||
Cable length, six‐wire configuration |
|
7.6 m as standard | ||||||
Material: Measuring body Cable entry Cable sheath |
|
stainless steel 2) stainless steel / neoprene PVC |
Tension / Compression Load Cell RSCC - datasheet | PDF, 0.38 Kb |