Type |
PWSE | |||||
Accuracy class |
C3MR | |||||
Max. number of scale intervals (nLC) |
3000 | |||||
Maximum capacity (Emax) |
kg |
100 |
200 |
300 |
500 |
750 |
Minimum scale division (vmin) |
g |
10 |
20 |
20 |
50 |
50 |
Temperature coefficient of zero signal (TK0) |
% of Cn / 10 K |
±0.0140 |
±0.0140 |
±0.0093 |
±0.0140 |
±0.0093 |
Platform size |
mm |
600 x 800 | ||||
Maximum platform size |
mm |
800 x 800 | ||||
Nominal (rated) sensitivity (Cn) |
mV/V |
2.0 ±0.2 | ||||
Zero signal (without initial load) |
0 ±0.1 | |||||
Temperature coefficient of sensitivity (TKC) In the range +20 ... +40°C [+68 ... +104°F] In the range -10 ... +20°C [+14 ... +68°F] |
% of Cn / 10 K |
±0.0170 ±0.0117 | ||||
Relative reversibility error (dhy) |
% of Cn |
±0.0166 | ||||
Relative linearity error (dlin) |
% of Cn |
±0.0166 | ||||
Relative creep over 30 min (dcr) |
% of Cn |
±0.0166 | ||||
Off-center load error |
±0.0100 | |||||
Input resistance (RLC) |
W |
390 ±15 | ||||
Output resistance (RO) |
359 ±10 | |||||
Reference excitation voltage (Uref) |
V |
5 | ||||
Nominal excitation voltage range (BU) |
1 ... 12 | |||||
Maximum excitation voltage |
15 | |||||
Insulation resistance (Ris) at 100 VDC |
GW |
> 2 | ||||
Nominal ambient temperature range (BT, nom) |
°C [°F] |
-10 ... +40 [+14 ... +104°F] | ||||
Operating temperature range (BT, G) |
-10 ... +50 [+14 ... +122°F] | |||||
Storage temperature range (BT, S) |
-25 ... +70 [-13 ... +158°F] | |||||
Limit load (EL) at 100 mm eccentricity |
% of Emax |
150 | ||||
Limit lateral loading (Elq), static |
300 | |||||
Breaking load (Ed) |
300 | |||||
Nominal (rated) displacement (snom) |
mm |
<0.5 | ||||
Weight (G), approx. |
kg |
0.9 |
0.9 |
1.1 |
1.2 |
1.2 |
Degree of protection per EN 60529 (IEC529) |
|
IP 67 | ||||
Cable length |
|
Standard 3 m | ||||
Material: Measuring body Cable sheath |
|
Stainless steel 1.4545 PVC |
Single Point Load Cell PWSE - datasheet | PDF, 0.09 Kb |