Type
|
FIT/1...
|
Accuracy class according to OIML R60
|
|
C3
|
Max. capacity (Emax)
Min. load cell verification interval (vmin)
Min. application range for 3000 d
|
kg
g kg
|
5
0.5
1.5
|
10
1
3
|
20
2
6
|
50
5
15
|
75
10
30
|
Max. platform size
|
mm
|
L 400 x W 400
|
L 600 x W500
|
Max. number of load cell verification intervals (nLC) Apportionment factor (pLC)
|
|
3000
1
|
Temperature effect on sensitivity (TKC)1) 2)
in temperature range 0 5C...+40 5C [32 5F...+104 5F]
Temperature effect on zero signal (TKS0)2)
|
% of Cn/10K
|
±0.0250
±0.0200
|
Hysteresis factor (dhy)1) 2)
Nonlinearity (dlin)1) 2)
Creep (dCR) over 30 min
Eccentric loading error acc. to OIML R76
|
% of C
|
±0.0166
±0.0166
±0.0166
±0.0233
|
Service load (EU); max. 120 mm eccentricity Safe load limit (EL); max. 20 mm eccentricity Permissible dyn. load (Fsrel)
max. 50 mm eccentricity
|
% of Emax
|
150
1000
70
|
Deflection at max. capacity (snom)
|
mm
|
< 0.15
|
Power supply:
Supply voltage UB1 (DC) Power consumption Switch-on current
|
V W A
|
+ 10 ... +30
� 2
0.2
|