Type
|
|
FIT/0...
|
Accuracy class according to OIML R60
|
|
C3
|
Max. capacity (Emax)
Min. load cell verification interval (vmin)
Min. application range for 3000 d
|
kg
g kg
|
5
0.5
1.5
|
10
1
3
|
20
2
6
|
50
5
15
|
75
10
30
|
Max. platform size
|
mm
|
L 400 x W 400
|
L 600 x W 500
|
Max. number of load cell verification intervals (nLC) Apportionment factor (pLC)
|
|
3000
1
|
Temperature effect on sensitivity (TKC)1) 2)
in temperature range 0 5C...+40 5C [32 5F...+104 5F]
Temperature effect on zero signal (TKS0)2)
|
% of Cn/10K
|
±0.0250
±0.0200
|
Hysteresis factor (dhy)1) 2)
Nonlinearity (dlin)1) 2)
Creep (dCR) over 30 min
Eccentric loading error acc. to OIML R76
|
% of C
|
±0.0166
±0.0166
±0.0166
±0.0233
|
Service load (EU); max. 120 mm eccentricity Safe load limit (EL); max. 20 mm eccentricity Permissible dyn. load (Fsrel)
max. 50 mm eccentricity
|
% of Emax
|
150
300 (without overload protection)
70
|
Deflection at max. capacity (snom)
|
mm
|
< 0.15
|
Power supply:
Supply voltage UB1 (DC) Power consumption Switch-on current
|
V W A
|
+ 10 ... +30
� 2
0.2
|
Resolution of meas. signal (1 Hz-Filter)
Measuring rate
Adjustable cut-off frequency of the digital filters: Filtermode 0
Filtermode 1 (response time 62 ... 365 ms) Baud rate (RS-232-, RS-485-interface)
Max. number of bus members
|
Bit
1/s
Hz Hz Baud
|
20
4 ... 1200
200 ... 0.25
18 ... 2.5
1200; 2400; 4800; 9600; 19200; 38400; 57600;
115200
90
|
CANOpen interface
Baud rate
|
Baud
|
Standard CiA DS301
10 000 ... 1 000 000
|
DeviceNet interface
Baud rate
|
Baud
|
Release 2.0 ODVA
125 000 ... 500 000
|
max. cable length (CANOpen, DeviceNet)
|
m
|
::; 5000 (10KBaud)... ::; 100 (500KBaud),
::; 25 (1MBaud)
|
Diagnostic channel, RS-485-2-wire (extended version E, plug 2)
Baud rate
max. cable length
Max. number of bus members
|
Baud m
|
38 400
500
90
|
Asynchronous serial interface (plug 1)
RS-485, 4 wire, max. cable length RS-232 max. cable length
|
m m
|
500
15
|
Trigger input (plug 1)
Permissible input voltage Low-level
High-level
Input resistance
|
V V V
kΩ
|
0 ... +12
< 1
> 4
10
|
Control inputs (extended version E, plug 2)
Permissible input voltage Low-level
High-level
Input resistance
|
V V V
kΩ
|
isolated, reference potential GND2
0 ... +30
< 6
>10
> 3
|
Control outputs (extended version E, plug 2)
External supply voltage UB2 Max. current of one output
Accumulated current of all outputs Voltage drop
|
V A A V
|
isolated, reference potential GND2
+11 ... +30
< 0.5
< 1.0
< 1
|