Type |
PW15AHi | |||
Accuracy class per OIML R60 |
|
C3 | ||
Maximum capacity 1) (Emax) Minimum scale division (vmin) Minimum utilization range for 3000 d |
kg g kg |
10 1 3 |
20 2 6 |
50 5 15 |
Max. platform size |
mm |
L500 x W400 | ||
Number of load cell verification intervals (nLC) Error fraction (pLC) |
|
3000 1 | ||
Temperature coefficient of sensitivity (TKC) 2)3) Temperature coefficient of zero signal (TKSO) 3) |
% of Cn/10 K |
±0.0250 ±0.0200 | ||
Relative reversibility error (dhy) 2)3) Non‐linearity (dlin) 2)3) Creep upon loading (dCR) over 30 min Off‐center load deviation per OIML R76 |
% of Cn |
±0.0166 ±0.0166 ±0.0166 ±0.0233 | ||
Service load (EU) at max. 120 mm eccentricity Limit load (EL) at max. 20 mm eccentricity Relative perm. vibrational stress (Fsrel) at max. 50 mm eccentricity |
% of Emax |
150 300
70 | ||
Nominal (rated) displacement (snom) |
mm |
<0.2 | ||
Voltage supply: Operating voltage UB1 (DC) Power consumption Start‐up current |
V W A |
+ 12 ... +30 < 1.5 0.15 | ||
Measurement signal resolution (1 Hz filter) Data rate Adjustable digital filter cut‐off frequency Baud rate (RS‐485 interface) Max. number of bus nodes |
Bit 1/s Hz Hz baud |
20 4 ... 1200 80 ... 0.0625 1200; 2400; 4800; 9600; 19200; 38400; 57600; 115200 32 | ||
CANopen interface Baud rate |
baud |
Standard CiA DS301 10 000 ... 1 000 000 | ||
DeviceNet interface Baud rate |
baud |
Release 2.0 ODVA 125 000 ... 500 000 | ||
Max. cable length (CANopen, DeviceNet) |
m |
::: 5000 (10 kbaud) ... ::: 100 (500 kbaud), ::: 25 (1 Mbaud) | ||
Asynchronous serial interface RS‐485, 4‐wire, max. cable length |
m |
500 | ||
Trigger input Permissible input voltage Low level High level Input resistance |
V V V k°W |
0 ... +12 < 1 > 4 10 | ||
Nominal (rated) ambient temperature range Operating temperature range Storage temperature range |
°C °C C |
- 10 ... + 40 - 10 ... + 50 - 25 ... + 75 | ||
EMC requirements
Degree of protection per EN 60529 Electrical connection Material Weight, approx. |
kg |
EN 45501, OIML R76 EN 61326-1/Tab. 4, Class B equipment EN 61326/A1, Tab. A1, equipment in industrial sectors IP 68 Device socket, made by Lumberg, 8 pin Steel 1 |
Digital Load Cell PW15AHi - datasheet | PDF, 0.13 Kb |