Type
|
SLB‐700A/06
|
SLB‐700A/12
|
Nominal (rated) measuring range
|
μm/m
|
0 … 500
|
Nominal (rated) sensitivity
|
mV/V
|
1.5 ±0.15
|
Relative zero signal error
|
%
|
5
|
Relative reversibility error
|
%
|
0.5
|
Relative linearity error
|
%
|
0.5
|
Effect of temperature on sensitivity, per 10 K
|
%
|
0.2
|
Effect of temperature on zero signal, per 10 K
|
%
|
0.2
|
Output resistance
|
Ω
|
1000 ±10
|
Input resistance
|
Ω
|
>1000
|
Insulation resistance
|
Ω
|
>5 ⋅ 1010
|
Nominal (rated) range of the excitation voltage
|
V
|
2 … 15
|
Nominal (rated) temperature range
|
°C
|
-10 … 40
|
Operating temperature range
|
°C
|
-20 … 60
|
Storage temperature range
|
°C
|
-40 … 85
|
Adapted to a material with a thermal expansion coefficient of
|
1/°C
|
12 ⋅10‐6
|
Maximum operating strain
|
μm/m
|
750
|
Restoring force
|
N
|
approx. 3110
|
Breaking strain
|
μm/m
|
1500
|
Max. permissible vibrational stress
per VDI/VDE 2638
|
%
|
150
|
Vibration
per DIN EN 60068‐2‐6
|
Hz
|
10 … 500
|
Maximum impact load
per DIN EN 60068‐2‐27
|
g
|
50
|
Degree of protection
per DIN EN 60529
|
IP65
|
Mounting bolt tightening torque
at least
nominal (rated) value
|
N⋅m N⋅m
|
8
16
|
Cable sheath
|
PUR
|
Cable length
|
m
|
6
|
12
|
Cable diameter
|
mm
|
3
|