Type |
T40HS | ||||
Accuracy class |
0.05 | ||||
Torque measuring system |
| ||||
Nominal (rated) torque Mnom |
N×m |
500 |
1000 |
2000 |
3000 |
|
| ||||
Nominal (rated) sensitivity (range between torque = zero and nominal (rated) torque)
Frequency output 10/ 60 / 240 kHz Voltage output
Sensitivity tolerance (deviation of the actual output quantity at Mnom from the nominal sensitivity) |
kHz V
% |
5 1) / 30 2) / 120 3)
10
± 0.1 | |||
Output signal at torque = zero Frequency output Voltage output |
kHz V |
10 1) / 60 2)/ 240 3)
0 | |||
Output signal at torque = zero Frequency output with positive nominal (rated) torque with negativ nominal (rated) torque Voltage output with positive nominal (rated) torque
with negative nominal (rated) torque |
kHz kHz
V V |
151) / 902) / 3603) ( 5V symmetrical 4) ) 51) / 302) / 1203) ( 5V symmetrical 4) )
+10…+12
-10…-12 | |||
Load resistance Frequency output Voltage output Long-term drift over 48 h Frequency output Voltage output |
kW kW
%
% |
³ 2
³ 10
< ±0.03
< ±0.03 | |||
Measurement frequency range ( -3dB ) Group delay |
µs |
11) / 32) / 63) < 4001) / < 2202) / < 1503) | |||
Residual ripple Voltage output 5) |
mV |
< 40 | |||
Effect of temperature per 10 K in the nominal (rated) temperature range on the output signal, related to the actual value of signal span
Frequency output Voltage output on the zero signal, related to the nominal (rated) sensitivity Frequency output
Voltage output |
%
%
%
% |
< ±0.05
< ±0.2
< ± 0.05
< ±0.1 |