Type |
|
WA2 |
WA10 |
WA20 |
WA50 |
WA100 |
WA200 |
WA300 |
WA500 |
Nominal displacement |
mm |
0...2 |
0...10 |
0...20 |
0...50 |
0...100 |
0...200 |
0...300 |
0...500 |
Nominal output span1) |
V |
9.5 (0.5...10) | |||||||
Output span tolerance1) Linearity deviation1) Greatest deviation between start and end point (including hysteresis by reference to nominal sensitivity) |
%
% |
±0.5
±0.2 | |||||||
Nominal temperature range Operating temperature range Effect of temperature1) on zero signal in nominal temperature range per 10 K, by reference to nominal sensitivity
Effect of temperature1) on output signal in nominal temperature range per 10 K, by reference to actual value |
°C °C
%
% |
-20...+60 -20...+70
::: ±0.15; typically <±0.10
::: ±0.15; typically <±0.10 | |||||||
Supply voltage Dependence of the nominal (rated) output range from the supply voltage, typically (in the supply voltage range) |
V % |
15...30 0.03 | |||||||
Burden in the output Current consumption Power consumption max. |
kΩ mA W |
�10 45 (typically 26) 1.5 | |||||||
Cut‐off frequency |
Hz |
520 filter 4th order, Butterworth | |||||||
Cable length between the transducer and the electronics |
m |
3...20 | |||||||
Cable length between the electronics and the evaluator |
m |
3...50 |
1) specified for the complete measuring chain
Inductive Displacement Sensor WA-T - datasheet | PDF, 0.12 Kb |