KontrollVahend ja Tehnika (KVT) OÜ
Exclusive representative
Hottinger Baldwin Messtechnik GmbH, Germany
+372 6006190
+372 6006680


Products

Digital weighing indicator WE2107

Special features

  • OIML test report to 6000 d
  • Use as 1, 2 or 3‐range scale
  • Four limit value switches with hysteresis
  • RS 232 interface
  • Two digital control inputs
  • Four digital outputs (limit value switches or filling/batching control)
  • Degree of protection IP65

Type

WE2107

Max. number of calibration values as per OIML R76 (Class III,

d = e

6000; Multirange

IIII)

d = e

2x3000; 3x2000

Multi‐range application

μV/e

≥ 0.6*)

Input sensitivity

Measuring range

mV/V

±2; max. ±3.2

Minimum load cell resistance

Ω

58

Maximum load cell resistance

Ω

4000

Load cell supply

VDC

5

Cable length between WE2107 and load cell(s)

m

max. 100 (206 m/mm2)*)

Data rate

FMD0

Cut‐off frequency (‐3 dB)

Meas./s

0.0625

0.125

0.25

200

2

4 8 25

Filter, adjustable,

Hz

0.5 1

Settling time

ms

16000

8000

4000

2000 1000

500 250 125 80

FMD1

Cut‐off frequency (‐3 dB)

Hz

2

2.5

3

4

5

6

7

8

10

Settling time

ms

566

450

380

310

240

170 160

150

140

Voltage supply without connected analog output Voltage supply with connected analog output Power consumption (incl. lighting)

VDC

VDC W

12...30; 24 nominal

18 ... 30; 24 nominal

6

Display

Character height

Status display

Keys

mm

LCD with backlighting

20

Zero, net, standstill, unit, range

Membrane keypad (tactile feedback)

Number of digital inputs

V

2

Input voltage IN1/2, Low

0...1.0

Input voltage IN1/2, High

V

3...30

Input resistance

10

Number of digital outputs (High side switch)

A V

4

Max. output current/output Voltage supply, outputs

0.6

12...30; 24 nominal

Interface (COM1) Baud rate, adjustable

Interface functions (COM2)

Bd

RS 232

1200 ... 38400

Print, serial display (automatic output), PC connection via RS 232

Analog output

mA

4 ... 20

Burden

Ω

100 ... 500

Resolution

bit

10

Nominal (rated) temperature range

°C

‐10 ... +50 (‐10 ... +40)*)

Operating temperature range

°C

‐20 ... +60

Storage temperature range

°C

‐40 ... +85

Connection/screw connection

4xPG7

Weight, approx.

kg

1

Degree of protection per EN 60 529 (IEC 529) Interference immunity (EMC) as per EN 45 501 (3 V/m) Housing material

IP65

Additionally tested to 10 V/m

ABS, halogen‐free

*) in accordance with OIML R76, legal for trade