Type |
AD101B | |
Accuracy class |
0.015 | |
Number of trade values, acc. to EN 455501 (R76) (with internal calibration) |
d |
6000 |
Input sensitivity |
µV/e |
1 |
Measuring range |
mV/V |
± 2.0 |
Input signal range |
± 3.0 | |
Measuring signal resolution, max. |
bit |
20 (at 1 Hz) |
Measuring rate (depending on output format and baud rate) |
Hz |
600 ... 4.7 |
Cut-off frequency of the digital filter (−3 dB), adjustable |
Hz |
40 ... 0.25 |
Bridge excitation voltage UB (Excitation from supply voltage) |
VDC |
5 ... 10 (= supply voltage!) |
Measuring signal input, Strain gage transducers |
Ω |
≥40...40001) |
(Full bridge) |
|
|
Transducer connection |
|
6-wire circuit |
Input resistance (differential) |
MΩ |
>15 |
Transducer cable length |
m |
≤ 100, in case of calibration incl. cable |
Interface cable length RS-232 |
m |
≤ 15 (25 pol. female connector) |
Calibration signal |
mV/V |
2 ± 0.01 % |
Temperature stability of the calibration signal |
ppm/°C |
::;2.5 |
Linearity error (related to full scale) |
% |
±0.01 |
Temperature effect on zero point (related to full scale) measuring sensitivity (related to actual value) |
%/10K |
typ. ± 0.005; max. 0.01 typ. ± 0.005; max. 0.01 |
Interface |
|
RS-232 |
Baud rate, adjustable |
bit/s |
1200 ... 38400 |
Supply voltage |
VDC |
5 ... 10 residual ripple ≤10 mV (p.p.) |
Current consumption (without load cell) |
mA |
≤ 80 |
Temperature range: |
°C [°F] |
−10...+40 [+14...+104] −20...+60 [−4...+140] |
Nominal temperature Service temperature | ||
Storage temperature |
−25...+85 [−13...185] | |
Dimensions |
mm |
93 x 53 x 17 |
Weight, approx. |
g |
40 |
Degree of protection according to EN 60529 (IEC 529) |
|
IP00 |
AD101B - datasheet | PDF, 0.15 Kb |