Type |
AED9301B | |
Measuring amplifier |
|
AD103C |
Measuring signal input |
mV/V |
±3, nominal ±2 |
Transducer connection: |
Ω |
≥80...4000 |
Strain gage transducer (full bridge) | ||
Transducer connection |
|
6-wire circuit |
Transducer cable length |
m |
≤100 |
Bridge excitation voltage |
VDC |
5 |
Profibus DP: Protocol Bit rate, max. Subcriber adress, can be set by rotary switch Interface cable length Profibus |
Mbit/s m |
Profibus-DP Slave, according to DIN 19245-3 12 3...99 1200 (at 9.6 / 19.2 / 93.75 kbit/s) 1000 (at 187.5 kbit/s) 400 (at 500 kbit/s) 200 (at 1.5 Mbit/s) 100 (at 12 Mbit/s) |
Diagnostics bus: |
kbit/s |
ASCII/Binary |
Protocol | ||
Baud rate |
38.4 | |
Node address |
|
0 ... 89 |
Length of Interface cable, max. |
m |
1000 |
Control inputs (electrically isolated): |
V |
2 |
Number | ||
Input voltage range, LOW |
0...5 | |
Input voltage range, HIGH |
V |
10...30 |
Input current, typ., HIGH−level = 24V |
mA |
12 |
Insulation voltage, typ. |
VDC |
500 |
Control outputs 1) (electrically isolated): |
A |
Supply from supply voltage |
Number |
4 | |
Max. output current Imax per output |
0.5 | |
Short circuit current, typ., Ub=24 V; RL <0.1 Ω |
A |
0.8 |
Short circuit duration |
|
Unlimited |
Input current at LOW level |
mA |
<2 |
Output voltage HIGH level |
V |
>15 at Imax |
Insulation voltage, typ. |
VDC |
500 |
Supply: |
VDC mA |
18...30 ≤250 2) |
Supply voltage Current consumption (withload cell, RB = 80 Ω, and | ||
addit. output current of control output Iout 1...4) | ||
Temperature range: Nominal temperature |
°C [°F] |
−10...+40 [+14...+104] |
Operating temperature |
−20...+60 [−4...+140] | |
Storage temperature |
−25...+85 [−13...+185] | |
Dimensions |
mm |
195 x 100 x 70 |
Weight, approx. |
g |
925 (without AD10x) |
Degree of protection according to EN 60529 (IEC 529) |
|
IP65 |
AED9301B - datasheet | PDF, 0.31 Kb |