Type |
PW16A... | ||||||||||
Accuracy class1) Number of load cell intervals (nLC) |
C3, C3MR | ||||||||||
3000 | |||||||||||
Max. capacity (Emax)* |
kg |
30 |
50 |
75 |
100 |
150 |
200 |
250 |
300 |
500 |
660 |
Minimum LC verification interval (vmin) Accuracy class C3 |
g |
5 |
10 |
10 |
20 |
20 |
50 |
50 |
50 |
100 |
100 |
Temperature effect on zero balance (TK0) Accuracy class C3 |
% of Cn / 10 K |
±0.0233 |
±0.0280 |
±0.0187 |
±0.0280 |
±0.0187 |
±0.0350 |
±0.0280 |
±0.0233 |
±0.0280 |
±0.0212 |
Minimum LC verification interval (vmin) Accuracy class C3MR |
g |
2 |
5 |
5 |
10 |
10 |
20 |
20 |
20 |
50 |
50 |
Temperature effect on zero balance (TK0) Accuracy class C3MR |
% of Cn / 10 K |
±0.0093 |
±0.0140 |
±0.0093 |
±0.0140 |
±0.0093 |
±0.0140 |
±0.0112 |
±0.0093 |
±0.0140 |
±0.0106 |
Max. platform size |
mm |
600 x 600 | |||||||||
Sensitivity (Cn) |
mV/V |
2.0 ±0.2 | |||||||||
Zero balance |
0 ±0.1 | ||||||||||
Temperature effect on sensitivity (TKC)2) Temperature range +20 ... +40 5C [+68 ... +104 5F] −10 ... +20 5C [+13 ... +68 5F] |
% of Cn / 10 K |
±0.0175 ±0.0117 | |||||||||
Hysteresis error (dhy)2) |
% of Cn |
±0.0166 | |||||||||
Non-linearity (dlin)2) |
±0.0166 | ||||||||||
Minimum dead load output return (DR) |
±0.0166 | ||||||||||
Off center load error3) |
±0.0233 | ||||||||||
Input resistance (RLC) |
Ω |
300 ... 500 | |||||||||
Output resistance (R0) |
300 ... 500 | ||||||||||
Reference excitation voltage (Uref) |
V |
5 | |||||||||
Nominal range of excitation voltage (BU) |
0 ... 12 | ||||||||||
Max. excitation voltage |
15 | ||||||||||
Insulation resistance (Ris) at 100 VDC |
GΩ |
> 2 | |||||||||
Nominal temperature range (BT) |
°C [°F] |
−10 ... +40 [+14 ... +104] | |||||||||
Service temperature range (Btu) |
−10 ... +50 [+14 ... +122] | ||||||||||
Storage temperature range (Btl) |
−25 ... +70 [−13 ... +158] | ||||||||||
Safe load limit (EL) |
% of Emax |
150 | |||||||||
Lateral limit force (Elq), static |
300 | ||||||||||
Breaking load (Ed) |
300 | ||||||||||
Deflection at Emax (snom), approx. |
mm |
< 0.5 | |||||||||
Weight (G), approx. |
kg |
1.8 | |||||||||
Protection class according to EN 60 529 (IEC 529) |
|
IP67 | |||||||||
Material: Measuring element Coating Cable sheath |
|
Aluminum Silicone rubber PVC |
Single Point Load Cell PW16A - datasheet | PDF, 0.23 Kb |