  • Stainless steel
  • Max. Capacities: 7.5 kg ... 200 kg
  • OIML R60 approval
  • Off center load compensated (OIML R76)
  • Protection class IP67 (acc. to EN 60 529)
  • 6-wire-technology
  • Meets EMC standards (EN 45 501)
  • Optional:

  • Reduced minimum LC verification interval (vmin) for multi range applications
  • Explosion proof versions
  • different cable lengths
  • Aligned output, suitable for con- nection in parallel

Type

PW15A...

Accuracy class 1)

Max. number of load cell interv. (nLC)

C3, C3MR

3000

Maximum capacity (Emax)2)

kg

7.5

15

20

30

50

75

100

150

200

Min. LC verific. interval (vmin) (Accuracy class C3)

g

1

2

5

5

10

10

20

20

50

Temperature effect

on zero balance (TK0), (Accuracy class C3)

% of Cn / 10 K

±0.0186

±0.0186

±0.0350

±0.0233

±0.0280

±0.0186

±0.0280

±0.0186

±0.0350

Min. LC verific. interval (vmin), (Accuracy class C3MR)

g

0.5

1

2

2

5

5

10

10

20

Temperature effect

on zero balance (TK0), (Accuracy class C3MR)

% of Cn / 10 K

±0.0093

±0.0093

±0.0140

±0.0093

±0.0140

±0.0093

±0.0140

±0.0093

±0.0140

Maximum platform size

mm

500 x 400

Sensitivity (Cn)

mV/V

2.0 ±0.2 (Option 6: A = 2 mV/V ±0.1 %)

Zero balance

0 ±0.1

Temperature effect on sensitivity (TKC) 3)

Temperature range:

+20 ... +40°C [+68 ... +104°F]

−10 ... +20°C [+14 ... +68°F]

% of Cn / 10 K

±0.0175

±0.0117

Hysteresis error (dhy) 3)

% of Cn

±0.0166

Non-linearity (dlin) 3)

±0.0166

Minimum dead load output return (DR)

±0.0166

Off center load error4)

±0.0233

Input resistance (RLC)

380 ±15

Output resistance (R0)

359 ±5 (Option 6: A = 359 Ω ±0.3 Ω)

Reference excit. voltage (Uref)

V

5

Nom. range of excit. volt. (BU)

1 ... 12

Max. excitation voltage

15

Insulation resist. (Ris) with 100 VDC

GΩ

> 1

Nominal temp. range (BT)

°C [°F]

−10 ... +40 [+14 ... +104°F]

Service temp. range (Btu)

−10 ... +50 [+14 ... +122°F]

Storage temp. range (Btl)

−25 ... +70 [−13 ... +158°F]

Safe load limit (EL) *)

*) at max. eccentricity

% of Emax

150

mm

160

Lateral load limit (Elq), static

% of Emax

300

Breaking load (Ed)

300

Deflect. at Emax (snom), app.

mm

< 0.5

Weight (G), approx.

kg

1.0

Protection class acc. to EN60529 (IEC529)

IP67

Material: Measuring element Coating

Cable sheath

Stainless steel Silicone rubber PVC